Skip to content

What Do “Dry Basis” and “As Received” Mean on a Peptide COA?

When a peptide certificate of analysis (COA) gives a percentage by mass, the footnote can change what that percentage means. As received uses the mass of the material in its reported condition, including any water present. Dry basis uses the dry mass defined by the laboratory’s method. Two reports can therefore show the same percentage while using different reference masses.

Where to find the reporting basis

Read the result row, its unit and any superscript together. Follow the superscript to the footnote or method section. A qualifier such as “as is” can appear there even when the result row shows only a percent sign. The note must apply to the specific result you are reading. A statement that the lab tested the sample “as received” can describe sample handling without establishing the basis for every value on the page.

Keep the laboratory’s exact wording. “Anhydrous basis” identifies a correction for water. For “dry basis,” check how the cited method defines the dry mass. A loss-on-drying value may include other volatile material. A separate water result elsewhere on the COA does not tell you whether the reported peptide result already includes a correction. Eurachem’s validation guide, p. 27, gives original and dried mass as examples of choices that help define the quantity being measured.

Two fictional COAs that both say 94%

These entries describe the same named analyte in two fictional lots. Read across each row as you would when comparing reports.

What each laboratory entry actually says
Report field Lot A Lot B
Quantity measured Target peptide mass fraction Target peptide mass fraction
Result 94% by mass 94% by mass
Footnote on this row As received Dry basis
Reference mass The material in its received condition The material on the method’s defined dry basis

Lot A’s reference mass includes its moisture. Lot B’s reference mass reflects the stated dry-basis adjustment. From these two rows alone, you cannot tell which lot has the higher peptide mass fraction on a common basis. Keep the footnotes attached to the values and ask the issuing lab whether it can supply comparable results.

Check what the percent sign measures

A mass fraction compares a defined analyte mass with a reference mass. An HPLC peak-area percentage compares a peak’s detector response with the total area included in the integration. If one document says “94% area” and another says “94% by mass,” establish which measurement answers your question before comparing the values. The HPLC chromatogram guide explains how to read an area table.

A 2023 peptide reference-standard study gives a worked theoretical example in which the authors report an anhydrous value and then account for water to express a value on an as-is basis. The authors treat water, counterions and chromatographic impurities as distinct contributions. Their example illustrates the reporting distinction. The two fictional lots above have no connection to the study. Reference Standards to Support Quality of Synthetic Peptide Therapeutics, Tables VII and VIII.

What to ask when the footnote is missing

Keep a copy of the original report and quote the lot, report revision, result row, value and unit in your question. For example, “For the target peptide mass fraction on this report, which reference mass did you use, and where is the basis defined?” Record the basis as unspecified until the laboratory clarifies it. Keep the response with the original, so another reader can trace the interpretation.

For the other fields that identify a report and its sample, see how to read a research peptide COA. Section 25 of the 2026 Eurachem/CITAC quality guide covers what a report needs to communicate for readers to interpret its results.

For qualified laboratory research only. Not for human or veterinary use.

CONTINUE YOUR REVIEW

Next steps for qualified researchers

Use the documentation resources below, then continue directly to the catalog to review products, prices, and matching COAs.

For qualified laboratory, analytical, educational, or institutional research only. Not for human or veterinary use.

JD BIOWORKS